Marantz PD5020D ユーザーズマニュアル

ページ / 68
46
20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BALANCE Gain Flag
02H
DATA02: BALANCE Gain
EAH: -22
FFH: -01
00H: 0
01H: +01
16H: +22
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BALANCE Gain Flag
02H
21. SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH
80H
60H
51H
01H
DATA00 CKS
DATA00: 02H: STADIUM
03H: ZOOM
04H: NORMAL
05H: FULL
06H: TRUE (REAL)
ACK
7FH
60H
80H
51H
01H
DATA00 CKS
DATA00: 02H: STADIUM
03H: ZOOM
04H: NORMAL
05H: FULL
06H: TRUE (REAL)
22. V. POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the
plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V. POSITION Gain Flag
01H
DATA02: V. POSITION Gain
C0H: -64
FFH: -01
00H: 0
01H: +01
40H: +64
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V. POSITION Gain Flag
01H
23. H. POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the
plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00  DATA01  DATA02  CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: H. POSITION Gain Flag
02H
DATA02: H. POSITION Gain
80H: -128
FFH: -01
00H: 0
01H: +01
7FH: +127
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: H. POSITION Gain Flag
02H
24. V-HEIGHT Gain Data
Function
The external control equipment changes the V-HEIGHT gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V-HEIGHT Gain Flag
07H
DATA02: V-HEIGHT Gain
00H: 0
40H: +64
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V-HEIGHT Gain Flag
07H
25. H-WIDTH Gain Data
Function
The external control equipment changes the H-WIDTH gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: H-WIDTH Gain Flag
08H
DATA02: H-WIDTH Gain
00H: 0
40H: +64
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: H-WIDTH Gain Flag
08H