INSTALLATION 
 
 
 
the data bit and then the remainder  is shifted  left one bit and the low-order  bit set to zero. If the result of 
that XOR is one, then the remainder  is XORed with the generator  polynomial. 
When the last bit of the checked  field is sent, the CRC in the generator  is inverted  and sent to the checker 
MSb  first.  When  the  last  bit  of  the  CRC  is  received  by  the  checker  and  no  errors  have  occurred,  the 
remainder  will be equal to the polynomial  residual. 
A CRC error exists  if the computed  checksum  remainder  at the end of a packet  reception  does not match  the 
residual. 
Bit stuffing requirements  must be met for the CRC, and this includes the need to insert a zero at the end of a 
CRC if the preceding  six bits were all ones. 
 
Token CRCs 
A  five-bit  CRC  field  is  provided  for  tokens  and  covers  the  ADDR  and  ENDP  fields  of IN,  SETUP,  and 
OUT tokens  or the time stamp field of an SOF token. The PING and SPLIT  special  tokens  also include  a 
five-bit CRC field. The generator  polynomial  is: 
G(X) = X
+ X
+ 1 
The binary  bit pattern  that represents  this polynomial  is 00101B.  If all token bits are received  without  error, 
the five-bit residual at the receiver will be 01100B. 
 
Data CRCs 
The data CRC is a 16-bit  polynomial  applied  over the data field of a data packet.  The generating 
polynomial  is: 
G(X) = X
16 
+ X
15 
+ X
+ 1 
The binary  bit pattern  that represents  this polynomial  is 1000000000000101B.  If all data and CRC bits are 
received without error, the 16-bit residual will be 1000000000001101B. 
 
 
 
6.3.3   Packet Format 
This section  shows packet  formats  for token,  data, and handshake  packets.  Fields  within  a packet  are 
displayed in these figures in the order in which bits are shifted out onto the bus. 
 
 
6.3.3.1  
Token Packet 
Figure  6-18  shows  the  field  formats  for  a  token  packet.  A  token  consists  of  a  PID,  specifying  either  IN, 
OUT,  or  SETUP  packet  type  and  ADDR  and  ENDP  fields.  The  PING  special  token  packet  also  has  the 
same fields as a token packet. For OUT and SETUP transactions,  the address and endpoint fields uniquely 
identify the endpoint that will receive the subsequent  Data packet. For IN transactions,  these fields uniquely 
identify  which  endpoint  should  transmit  a  Data  packet.  For  PING  transactions,  these  fields  uniquely 
identify  which  endpoint  will  respond  with  a  handshake  packet.  Only  the  host  can  issue  token  packets.  An 
IN  PID  defines  a  Data  transaction  from  a  function  to  the  host.  OUT  and  SETUP  PIDs  define  Data 
transactions  from the host to a function.  A PING PID defines  a handshake  transaction  from the function  to 
the host. 
 
 
 
 
 
 
 
 
Figure 6-18: Token Format 
 
Token packets  have a five-bit  CRC that covers  the address  and endpoint  fields as shown above.  The CRC 
does  not  cover  the  PID,  which  has  its  own  check  field.  Token  and  SOF  packets  are delimited  by  an  EOP 
after  three  bytes of packet  field data. If a packet  decodes  as an otherwise  valid  token  or SOF  but does not 
terminate  with an EOP after three bytes, it must be considered invalid and ignored by the receiver.