Seagate ST2000VN000 ユーザーズマニュアル

ページ / 40
20
NAS HDD Product Manual, Rev. A
Drive Specifications
2.12 Reliability - Mean Time Between Failure
The product will achieve a Mean Time Between Failure Rate (MTBF) of 1,000,000 hours when operated in an 
environment of ambient air temperatures of 25°C. Operation at temperatures outside the specifications shown in 
• MTBF specifications are based on the following assumptions for NAS environments:
• 8760 power-on hours per year
• 10,000 average motor start/stop cycles per year
• Operations at nominal voltages
• Temperatures outside the specifications in 
Operation at excessive I/O duty cycle may degrade product reliability. The NAS environment of power-on hours, 
temperature, and I/O duty cycle affect the product MTBF. The MTBF will be degraded if used in an enterprise 
application.
2.13 Warranty
From this page, click on the “Verify Your Warranty” link. You will be asked to provide the drive serial number, 
model number (or part number) and country of purchase. The system will display the warranty information for your 
drive.
2.14 Agency certification
2.14.1 Safety certification
These products are certified to meet the requirements of UL60950-1, CSA60950-1 and EN60950 and so marked 
as to the certify agency.
2.14.2 Electromagnetic compatibility
Hard drives that display the CE mark comply with the European Union (EU) requirements specified in the 
Electromagnetic Compatibility Directive (2004/108/EC) as put into place 20 July 2007. Testing is performed to the 
levels specified by the product standards for Information Technology Equipment (ITE). Emission levels are defined 
by EN 55022, Class B and the immunity levels are defined by EN 55024.
Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the 
directives when used in the test systems, we cannot guarantee that all systems will comply with the directives. 
The drive is designed for operation inside a properly designed enclosure, with properly shielded I/O cable (if 
necessary) and terminators on all unused I/O ports. Computer manufacturers and system integrators should 
confirm EMC compliance and provide CE marking for their products.
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m, 
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 
200Hz
A
EN61000-4-3: 96
ENV50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common,
AC mains
B
EN61000-4-5: 95
Conducted RF immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz 
sine
A
EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94
Table 5 Radio frequency environments