Seagate ST3000DM00 ユーザーズマニュアル

ページ / 44
22
Barracuda SATA Product Manual, Rev. D
Drive Specifications
2.10.1 Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this 
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-
7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation of 
tone ratios according to Annex D of the ECMA-74 standards.
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in 
Table 8
.
2.12 Warranty
From this page, click on the “Verify Your Warranty” link. You will be asked to provide the drive serial number, 
model number (or part number) and country of purchase. The system will display the warranty information for your 
drive.
2.13 Agency certification
2.13.1 Safety certification
These products are certified to meet the requirements of UL60950-1, CSA60950-1 and EN60950 and so marked 
as to the certify agency.
2.13.2 Electromagnetic compatibility
Hard drives that display the CE mark comply with the European Union (EU) requirements specified in the 
Electromagnetic Compatibility Directive (2004/108/EC) as put into place 20 July 2007. Testing is performed to the 
levels specified by the product standards for Information Technology Equipment (ITE). Emission levels are defined 
by EN 55022, Class B and the immunity levels are defined by EN 55024.
Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the 
directives when used in the test systems, we cannot guarantee that all systems will comply with the directives. 
The drive is designed for operation inside a properly designed enclosure, with properly shielded I/O cable (if 
necessary) and terminators on all unused I/O ports. Computer manufacturers and system integrators should 
confirm EMC compliance and provide CE marking for their products.
Table 8 Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m, 
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 
200Hz
A
EN61000-4-3: 96
ENV50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common,
AC mains
B
EN61000-4-5: 95
Conducted RF immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz 
sine
A
EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94