2.9
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). Discrete 
tone penalties are added to the A-weighted sound power (LW) with the following formula only when determin-
ing compliance: 
LWt(spec) == LW + 0.1Pt + 0.3 < 4.0 (Bels)
where 
LW = A-weighted sound power level
pt == Value of discrete tone penalty [==dLt-6.0 (dBA)]
dLt = Tone-to-noise ratio taken in accordance with ISO 7779 at each octave band.
All measurements are consistent with ISO document 7779. Sound power measurements are taken under 
essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing 
upward.
)
2.10
Electromagnetic immunity
 
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 6: 
Drive level acoustics
Acoustic mode
Idle
Operational
1.6 bels (typ)
2.2 bels (typ)
Table 7: 
Electromagnetic immunity
Test
Description
Performance
 
level
Reference
 
standard
Radiated RF immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 
Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 
kHz sine
A
EN 61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
 
0% short, 5 seconds
 
40%, 0.10 seconds
 
70%, 0.01 seconds
C
 
C
 
C
 
B
EN 61000-4-11: 94