Seagate ST3000NC002 ユーザーズマニュアル

ページ / 43
Constellation CS Serial ATA Product Manual, Rev. C
18 
2.10
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are
consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a
reflecting plane. For all tests, the drive is oriented with the cover facing upward.
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational
levels.
2.11
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use
of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-7) to discern tone audibility and
to compensate for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-
74 standards.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when
subjected to the radio frequeny (RF) environments defined in 
.
Note
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the 
following equation: 
(Number of seeks per second = 0.4 / (average latency + average access time
Table 3 Fluid Dynamic Bearing (FDB) motor acoustics
Idle*
Performance Seek
3 Disks
(3TB)
2.5 bels (typical)
2.6 bels (max)
2.5 bels (typical)
2.6 bels (max)
2 Disk
(2TB)
2.4 bels (typical)
2.5 bels (max)
2.4 bels (typical)
2.5 bels (max)
1 Disk
(1TB)
2.2 bels (typical)
2.3 bels (max)
2.2 bels (typical)
2.3 bels (max)
Table 4 Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN61000-4-2: 95
Radiated RF immunity
80MHz to 1,000MHz, 3 V/m, 
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 200Hz
A
EN61000-4-3: 96
ENV50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common,
AC mains
B
EN61000-4-5: 95
Conducted RF immunity
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz 
sine
A
EN61000-4-6: 97
Voltage dips, interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94