Seagate ST9500323CS ユーザーズマニュアル

ページ / 46
Pipeline HD Mini Series SATA Product Manual, Rev. E                                                                                             
11
2.10.5
Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mount-
ing screws. Shock may be applied in the X, Y or Z axis.
2.10.5.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operat-
ing shock of 350 Gs based on half-sine shock pulses of 2 msec. Shocks should not be repeated more than two 
times per second.
2.10.5.2
Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in 
performance when subsequently put into operation is 800 Gs based on a nonrepetitive half-sine shock pulse of 2 
msec duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in 
performance when subsequently put into operation is 800 Gs based on a nonrepetitive half-sine shock pulse of 1 
msec duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in 
performance when subsequently put into operation is 600 Gs based on a nonrepetitive half-sine shock pulse of 0.5 
msec duration. 
2.10.6
Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive 
mounting screws. Vibration may be applied in the X, Y or Z axis.
2.10.6.1
Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards specified in 
this document are specified below.
2.10.6.2
Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degradation in 
performance when subsequently put into operation are specified below
.
2.11
Acoustics
Drive emission of sound is measured consistent with the ECMA-74 and its’ referenced standards. Testing is con-
ducted at room temperature (approximately 25
°
C). Emission levels are reported as the total A-weighted sound 
power levels for steady state, idle, and active seek modes of operation.
5–500 Hz
1.0 Gs (0 to peak). Max displacement may apply below 10 Hz.
5–500 Hz:
5.0 Gs (0 to peak). Max displacement may apply below 22 Hz.
Table 5: 
Drive A-weighted Sound Power Levels (SWL, BA)
ST9500323CS and ST9320328CS
ST9250311CS and ST91603110CS
Idle*
CE seek
Idle*