Seagate ST9200011FS ユーザーズマニュアル

ページ / 50
14
Pulsar Product Manual, Rev. A
2.9.6
Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the 
drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.9.6.1
Operating vibration
The maximum random vibration levels that the drive may experience while meeting the performance standards 
specified in this document are specified below. This specification does not cover connection issues that may 
result from testing at this level.
2.9.6.2
Nonoperating vibration
The maximum random nonoperating vibration levels that the drive may experience without incurring physical 
damage or degradation in performance when subsequently put into operation are specified below.
2.10
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
20–2000 Hz
16 Grms
20–2000 Hz
16 Grms
Table 5: 
Radio frequency environments
Test
Description
Performance level
Reference standard
Electrostatic 
discharge
Contact, HCP, VCP: ± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF 
immunity
80 to 1000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast 
transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF 
immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine
A
EN 61000-4-6: 97
Voltage dips, 
interrupts
0% open, 5 seconds
 
0% short, 5 seconds
 
40%, 0.10 seconds
 
70%, 0.01 seconds
C
 
C
 
C
 
B
EN 61000-4-11: 94