Seagate ST9160823ASG ユーザーズマニュアル

ページ / 46
12
Momentus 7200.2 SATA Product Manual, Rev. E
2.10.5
Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive 
mounting screws. Shock may be applied in the X, Y or Z axis.
Note.
Additional shock protection is provided by the Free Fall Protection feature on ST9200420ASG, 
ST9160823ASG and ST980813ASG models. See Section 2.13.1 for additional information about 
this feature.
2.10.5.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum 
operating shock of 300 Gs based on half-sine shock pulses of 2 msec. Shocks should not be repeated more 
than two times per second.
2.10.5.2
Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 800 Gs based on a nonrepetitive half-sine shock pulse 
of 2 msec duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 900 Gs based on a nonrepetitive half-sine shock pulse 
of 1 msec duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 400 Gs based on a nonrepetitive half-sine shock pulse 
of 0.5 msec duration. 
2.10.6
Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the 
drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.10.6.1
Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards speci-
fied in this document are specified below.
2.10.6.2
Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degrada-
tion in performance when subsequently put into operation are specified below
.
5–500 Hz
1.0 G (0 to peak). Max displacement may apply below 10 Hz.
5–500 Hz: