Seagate ST9320310AS ユーザーズマニュアル

ページ / 44
Momentus Product Manual, Rev. D
27
5.3.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data is organized as a single 512-byte (for ST9640320AS, ST9500320AS, ST9320310AS, 
ST9250310AS and ST9160316AS models) or 4096-byte (for ST9640322AS, ST9320312AS and 
ST9400321AS models) block of data, whose contents are shown in the table on page 27. All reserved bits or 
words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive.
The following commands contain drive-specific features that may not be included in the Serial ATA specifica-
tion.
Word
Description
Value
 
 
0
Configuration information:
 
• Bit 15: 0 = ATA; 1 = ATAPI
 
• Bit 7: removable media
 
• Bit 6: removable controller
 
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
 = none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision (8 ASCII character string, padded with 
blanks to end of string)
x.xx
27–46
Drive model number: (40 ASCII characters, padded with 
blanks to end of string)
ST9640322AS
 
ST9640320AS
 
ST9500320AS
 
ST9400321AS
 
ST9320312AS
 
ST9320310AS
 
ST9250310AS
 
ST9160316AS
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple 
and Write multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be dis-
abled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical cylinders 
xxxx
H
55
Number of current logical heads 
xxxx
H
56
Number of current logical sectors per logical track
xxxx
H