Seagate ST92505610AS ユーザーズマニュアル

ページ / 44
14
Momentus XT Product Manual, Rev. B
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and 
power to operational levels.
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this pro-
cess is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to 
discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone 
ratios according to Annex D of the ECMA-74 standards.
*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
2.13
Reliability 
Measurement type
Specification
Nonrecoverable read errors
1 per 10
14
 bits read, max.
Annualized Failure Rate (AFR)
0.5%
Load/Unload (U/UL)
 
 
25°C, 50% relative humidity
 
 
 
32°C, 80% relative humidity 
 
5°C, 80% relative humidity 
 
5°C, 10% relative humidity 
 
55°C, 16% relative humidity 
 
 
600,000 software-controlled power on/off cycles
 
50,000 hard power on/off cycles
 
 
600,000 software-controlled power on/off cycles
 
50,000 hard power on/off cycles
 
 
Warranty
To determine the warranty for a specific drive, use a web browser to access the 
following web page: 
support.seagate.com/customer/warranty_validation.jsp
You will be asked to provide the drive serial number, model number (or part num-
ber) and country of purchase. After submitting this information, the system will dis-
play the warranty information for your drive
 
Table 6: 
Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: 
± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz 
sine
A
EN 61000-4-6: 97
Power Frequency H-field 
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
 
>95% Reduction for 250 cycles
 
>95%, 0.5 cycles
C
 
C
 
B
EN 61000-4-11: 94