Power dissipation
1TB model drive in 3Gb operation
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 
5). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 
3.4123. 
Figure 3. 
1TB Models (3Gb) DC current and power vs. input/output operations per second
Note.
For power details about SED vs. non-SED drive, please refer to section 7.8.