EE25 Series Product Manual, Rev. E
4.1.2
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data, shown below, is organized as a single 512-byte block of data. All reserved bits or words 
should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive. See 
Section 2.0 on page 3 for
 default parameter settings.
The following commands contain drive-specific features that may not be included in the ATA-6 Standard.   
 
       
Word
Description
Value
0
Configuration information:
 
• Bit 15: 0 = ATA; 1 = ATAPI
 
• Bit 7: removable media
 
• Bit 6: removable controller
 
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
 = none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision
 
(8 ASCII character string, padded with blanks to end of string)
x.xx
27–46
Drive model number (40 ASCII characters, padded with blanks 
to end of string)
ST940813AM
 
ST940814AM
 
ST930813AM
 
ST930814AM
 
ST920813AM
 
ST920814AM
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and 
Write multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be disabled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical cylinders 
xxxx
H
55
Number of current logical heads 
xxxx
H
56
Number of current logical sectors per logical track
xxxx
H