Seagate ST500LT033 ユーザーズマニュアル

ページ / 32
S
EAGATE 
L
APTOP 
U
LTRATHIN 
HDD SATA P
RODUCT 
M
ANUAL
, R
EV
. A
  11
 D
RIVE 
S
PECIFICATIONS 
2.9
A
COUSTICS
Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is conducted at room 
temperature (approximately 25°C). Emission levels are reported as the total A-weighted sound power levers for steady state, idle, and 
active seeks modes of operation.
2.9.1
Test for prominent discrete tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the 
absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to discern tone audibility and to compensate for the 
inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards.
*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.
2.10
E
LECTROMAGNETIC 
I
MMUNITY
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected 
to the radio frequency (RF) environment as defined in 
I
DLE
(1)
1.
During periods of drive idle, some offline activity may occur according to the S.M.A.R.T.  
specification, which may increase acoustic and power to operational levels.
P
ERFORMANCE 
S
EEK
2.0 bels (typ)
2.2 bels (max)
2.2 bels (typ)
2.4 bels (max)
Table 4
Radio Frequency Environments
 
T
EST
D
ESCRIPTION
P
ERFORMANCE
L
EVEL
R
EFERENCE 
S
TANDARD
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m,  
80% AM with 1 kHz sine 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine
A
EN 61000-4-6: 97
Power Frequency H-field 
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles 
>95% Reduction for 250 cycles 
>95%, 0.5 cycles
C
C
B
EN 61000-4-11: 94