Seagate ST500LX003 ユーザーズマニュアル

ページ / 42
14
Momentus XT Product Manual, Rev. D
3.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
3.13
Reliability 
Measurement type
Specification
Nonrecoverable read errors
1 per 10
14
 bits read, max.
Annualized Failure Rate (AFR)
0.5%
Load/Unload (U/UL)
 
 
25°C, 50% relative humidity
 
 
 
32°C, 80% relative humidity 
 
5°C, 80% relative humidity 
 
5°C, 10% relative humidity 
 
55°C, 16% relative humidity 
 
 
600,000 software-controlled power on/off cycles
 
50,000 hard power on/off cycles
 
 
600,000 software-controlled power on/off cycles
 
50,000 hard power on/off cycles
 
 
Warranty
To determine the warranty for a specific drive, use a web browser to access the 
following web page:
 
From this page, click on the “Verify Your Warranty” link. You will be asked to pro-
vide the drive serial number, model number (or part number) and country of pur-
chase. The system will display the warranty information for your drive.
 
Table 6: 
Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: 
± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz 
sine
A
EN 61000-4-6: 97
Power Frequency H-field 
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
 
>95% Reduction for 250 cycles
 
>95%, 0.5 cycles
C
 
C
 
B