5
See “Conducted noise immunity” in the 
Cheetah 4LP Product
Manual. The specified voltage tolerance is inclusive of ripple,
noise, and transient response.
6
At power-up, the motor current regulator limits the +12V cur-
rent to an average value of less than value shown in table,
although instantaneous peaks may exceed this value. These
peaks should measure 5 msec duration or less.
7
Minimum current loading for each supply voltage is not less
than 4% of the maximum operating current shown.
8
Use separate ground returns for +5V and +12V supplies.
9
Where power is provided to multiple drives from a common
supply, carefully consider individual-drive power requirements.
Where multiple units are powered on simultaneously, be sure
the peak starting current is available to each device.
10
No terminator power. See 11.7.3.4 in the 
Cheetah 4LP Prod-
uct Manual.
Table 3.
Dimensions of the drive
in
mm
Height
1.00
25.4
Width
4.00
101.6
Depth
5.75
146.05
Weight 1.3 lb (0.59 kg)