Seagate ST6000NM0084 ユーザーズマニュアル

ページ / 45
Seagate Enterprise Capacity 3.5 HDD v4 Serial ATA Product Manual, Rev. C
  15
  
2.6
Environmental limits
Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. 
Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C).
2.6.1
Temperature
a. Operating
41°F to 140°F (5°C to 60°C) drive case temperature range with a maximum temperature gradient of 36°F (20°C) per hour. 
The maximum allowable drive case temperature is 140°F (60°C).
required cooling is provided for the electronics and HDA, place the drive in its final mechanical configuration, and perform 
random write/read operations. After the temperatures stabilize, measure the case temperature of the drive. See Figure 7 
for HDA temperature checkpoint.
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification 
assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.
HDA Temp.
Check Point
 
Figure 7. 
Location of the HDA temperature check point
Note
Image is for reference only, may not represent actual drive
2.6.2
Humidity
The values below assume that no condensation on the drive occurs. Maximum wet bulb temperature is 84.2°F (29°C).
2.6.2.1
Relative humidity
Operating:
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
Nonoperating:
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
2.6.3
Effective Altitude (sea level)
 
Operating:
–304.8 m to 3048 m (–1000 ft. to 10,000+ ft.)
Nonoperating:
–304.8 m to 12,192 m (–1000 ft. to 40,000+ ft.)
 
Note