Seagate ST9750424AS ユーザーズマニュアル

ページ / 44
14
Momentus Product Manual, Rev. C
3.10.6
Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive 
mounting screws. Shock may be applied in the X, Y or Z axis.
Note.
Additional shock protection is provided by the Free Fall Protection feature on ST9750423ASG, 
ST9750420ASG, ST9640423ASG and ST9500423ASG models. See Section 3.13.1 for additional 
information about this feature.
3.10.6.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum 
operating shock of 350 Gs based on half-sine shock pulses of 2ms. Shocks should not be repeated more than 
one time per axis.
3.10.6.2
Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 800 Gs based on a nonrepetitive half-sine shock pulse 
of 2 ms duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 1000 Gs based on a nonrepetitive half-sine shock 
pulse of 1 ms duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 1000 Gs based on a nonrepetitive half-sine shock 
pulse of 0.5 ms duration. 
3.10.7
Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the 
drive mounting screws. Vibration may be applied in the X, Y or Z axis.
3.10.7.1
Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards speci-
fied in this document are specified below.
3.10.7.2
Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degrada-
tion in performance when subsequently put into operation are specified below
.
5–200 Hz
2.0 Gs (0 to peak). Max displacement may apply below 10 Hz.
200–500 Hz
1.0 Gs (0 to peak).
5–500 Hz:
5 Gs (0 to peak). Max displacement may apply below 22 Hz.