Seagate ST660712DE ユーザーズマニュアル

ページ / 48
28
ST1.3 Series Product Manual, Rev. C
4.1.2
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data is organized as a single 512-byte block of data, whose contents are shown in the table on 
page 28. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or 
vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.
The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard.
 
Word
ATA specification
Value
0
Configuration information:
 
• Bit 15: 0 = ATA; 1 = ATAPI
 
• Bit 7: removable media
 
• Bit 6: removable controller
 
• Bit 0: reserved
848A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4-5
Retired
0000
H
6
Number of logical sectors per logical track
003F
H
7-9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
 = none)
ASCII
20
Retired
0003
H
21
Retired
0100
H
22
Obsolete
0004
H
23–26
Firmware revision (8 ASCII character string, padded with blanks to end of string)
x.xx
27–46
Drive model number: 
 
(40 ASCII characters, padded with blanks to end of string)
ST612712DEG, 
ST612712DE, 
ST610712DEG, 
ST610712DE, 
ST680712DEG, 
ST680712DE, 
ST660712DEG, 
ST660712DE
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and Write multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be disabled
0B00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54-58, 64–70 and 88 valid
0007
H
54
Number of current logical cylinders
xxxx
H
55
Number of current logical heads
xxxx
H
56
Number of current logical sectors per logical track
xxxx
H
57-58
Current capacity in sectors
xxxx
H