Seagate ST760211DE ユーザーズマニュアル

ページ / 44
Lyrion Series IDE Product Manual, Rev. E
27
4.2.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data is organized as a single 512-byte (256 word) block of data, whose contents are as shown 
in the following table.
Word 
ATA specification 
Value 
0 General 
configuration 
information 
bit-significant 
information 
 Bit 15: 0 = ATA device  
 Bit 7:   1 = removable media 
 Bit 6:   1 = non-removable/fixed device  
0040h 
10–19  Serial number: (20 ASCII characters) 
Serial number 
23–26  Firmware revision (8 ASCII character string) 
Firmware revision 
27–46  Drive model number:  
(40 ASCII characters, padded with blanks to end of string) 
Model number 
47 
Bits 7-0: Maximum number of sectors transferred per interrupt on 
               Read Multiple/ Write Multiple commands 
8010h 
49 Capabilities 
 
Bit 13: 1= Standby timer values specified in ATA-7 are supported 
Bit 11: 1= IORDY supported 
Bit 10: 0= IORDY may not be disabled 
Bit 9  : 1= LBA supported 
Bit 8  : 1= DMA supported 
2B00h 
53 
Bit 2: 1= the fields reported in word 88 are valid 
Bit 1: 1= the fields reported in words (70:64) are valid 
0007h 
59 
Bit 8: 1=  Multiple sector setting is valid 
Bits 7-0:  Current setting for number of sectors transferred during a
                Read/Write Multiple command  
0110h 
60–61  Total number of user-addressable LBA sectors available 
37E3E40h (30GB) 
6FC7C80h (60GB) 
63 
Bit 10: 1= Multiword DMA mode 2 is selected 
           0= Multiword DMA mode 2 is not selected 
Bit 9:   1= Multiword DMA mode 1 is selected 
           0= Multiword DMA mode 1 is not selected 
Bit 8:   1= Multiword DMA mode 0 is selected 
           0= Multiword DMA mode 0 is not selected 
Bit 2:   1= Multiword DMA mode 2 and below are supported 
Bit 1:   1= Multiword DMA mode 1 and below are supported  
Bit 0:   1= Multiword DMA mode 0 is supported 
xxx7h 
64 
Bits 7-0: PIO modes supported 
0003h 
65 
Minimum Multiword DMA transfer cycle time per word 
Bits 15-0: Cycle time in nanoseconds 
0078h 
66 
Recommended Multiword DMA transfer cycle time 
Bits 15-0: Cycle time in nanoseconds 
0078h 
67 
Minimum PIO transfer cycle time without flow control 
Bits 15-0: Cycle time in nanoseconds 
0078h 
68 
Minimum PIO transfer cycle time with IORDY flow control 
Bits 15-0: Cycle time in nanoseconds 
0078h