Seagate ST936751SS ユーザーズマニュアル

ページ / 86
Savvio 15K SAS Product Manual, Rev. B
49
9.3.1
Inquiry data 
Table 8 lists the Inquiry command data that the drive should return to the initiator per the format given in the 
SAS Interface Manual.
Table 8: 
Savvio inquiry data  
*
Copyright year (changes with actual year).
**
SCSI Revision support. See the appropriate SPC release documentation for definitions.
PP
10 = Inquiry data for an Inquiry command received on Port A.
30 = Inquiry data for an Inquiry command received on Port B.
R#
Four ASCII digits representing the last four digits of the product firmware release number.
S#
Eight ASCII digits representing the eight digits of the product serial number.
[ ]
Bytes 16 through 25 reflect model of drive. The table above shows the hex values for Model ST973451SS.
Refer to the values below for the values of bytes 16 through 25 of you particular model:
ST973451SS
53 54 39 37 33 34 35 31 53 53
ST936751SS
53 54 39 33 36 37 35 31 53 53
9.3.2
Mode Sense data 
The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The 
drive maintains four sets of mode parameters:
1.
Default values
Default values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the 
drive’s PCB. These default values can be changed only by downloading a complete set of new firmware 
into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use 
those in a Mode Select command to set up new current and saved values, where the values are change-
able.
2.
Saved values
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that 
are allowed to be changed can be changed by this method. Parameters in the saved values list that are not 
changeable by the Mode Select command get their values from default values storage.
When power is applied to the drive, it takes saved values from the media and stores them as current val-
ues in volatile memory. It is not possible to change the current values (or the saved values) with a Mode 
Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a 
“Check Condition” status.
Bytes
Data (hex)
0-15
00
00
03**
12
8B
00
PP
0A
53
45
41
47
41
54
45
20
Vendor ID
16-31
[53
54
39
37
33
34
35
31
53
53
20
20
20
20
20
20
Product ID
32-47
R#
R#
R#
R#
S#
S#
S#
S#
S#
S#
S#
S#
00
00
00
00
48-63
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
64-79
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00
80-95
00 
00 
00 
00
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00 
00
96-111
00 
43 
6F 
70  
79 
72 
69 
67 
68 
74 
20 
28 
63 
29 
20 
32*
*Copyright
112-127
30*
30*
36*
20
53 
65 
61 
67 
61 
74
65
20
41
6C
6C
20
notice
128-143
72 
69 
67 
68
74 
73 
20 
72 
65 
73 
65 
72 
76 
65 
64 
20