Seagate ST980811AS ユーザーズマニュアル

ページ / 44
Momentus 5400.3 SATA Product Manual, Rev. D
13
2.11
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially 
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is 
defined by the following equation: 
 
 
(Number of seeks per second = 0.4 / (average latency + average access time))
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and 
power to operational levels.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5: 
Drive level acoustics
Models
Idle*
Performance seek
2 discs
ST9160821AS
 
ST9120822AS
 
ST9100828AS
2.4 bels (typ)
 
2.6 bels (max)
3.0 bels (typ)
 
3.2 bels (max)
1 disc
ST980811AS
 
ST960813AS
 
ST940814AS
2.2 bels (typ)
 
2.4 bels (max)
2.9 bels (typ)
 
3.1 bels (max)
Table 6: 
Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: 
± 
4
 
kV; Air:
 
± 
8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 
1 kV on AC mains, 
± 
0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 
1 kV differential, 
±
 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz 
sine
A
EN 61000-4-6: 97
Power Frequency H-field 
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
 
>95% Reduction for 250 cycles
 
>95%, 0.5 cycles
C
 
C
 
B
EN 61000-4-11: 94