Seagate ST940210A ユーザーズマニュアル

ページ / 50
LD25 Series 5400.2 Product Manual, Rev. C
13
2.9.5
Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive 
mounting screws. Shock may be applied in the X, Y or Z axis.
2.9.5.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum 
operating shock of 175 Gs based on half-sine shock pulses of 2 msec. Shocks should not be repeated more 
than two times per second.
2.9.5.2
Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 500 Gs based on a nonrepetitive half-sine shock pulse 
of 2 msec duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 350 Gs based on a nonrepetitive half-sine shock pulse 
of 1 msec duration. 
The nonoperating shock level that the drive can experience without incurring physical damage or degradation 
in performance when subsequently put into operation is 200 Gs based on a nonrepetitive half-sine shock pulse 
of 0.5 msec duration. 
2.9.6
Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the 
drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.9.6.1
Operating vibration
The following table lists the maximum vibration levels that the drive may experience while meeting the perfor-
mance standards specified in this document.
2.9.6.2
Nonoperating vibration
The following table lists the maximum nonoperating vibration that the drive may experience without incurring 
physical damage or degradation in performance when subsequently put into operation.
5–350 Hz
0.5 Gs
351-500 Hz
0.25 Gs
10–350 Hz
5.0 Gs
351-500 Hz
1.0 G