Seagate ST9320328CS ユーザーズマニュアル

ページ / 46
12
Pipeline HD Mini Series SATA Product Manual, Rev. E
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power 
to operational levels.
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process 
is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to discern tone 
audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to 
Annex D of the ECMA-74 standards.
*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in perfor-
mance when subjected to the radio frequency (RF) environments defined in the following table:
2.1 bels (typ) 
2.2 bels (max)
2.3 bels (typ) 
2.4 bels (max)
2.0 bels (typ) 
2.1 bels (max)
2.1 bels (typ) 
2.2 bels (max)
Table 6: 
Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: 
± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m,  
80% AM with 1 kHz sine 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz 
sine
A
EN 61000-4-6: 97
Power Frequency H-field 
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles 
>95% Reduction for 250 cycles 
>95%, 0.5 cycles
B
EN 61000-4-11: 94
Table 5: 
Drive A-weighted Sound Power Levels (SWL, BA)