Seagate ST9320328CS ユーザーズマニュアル

ページ / 46
Pipeline HD Mini Series SATA Product Manual, Rev. E                                                                                             
29
Note.
At power-on, or after a hardware or software reset, the default values of the features are as indicated 
above. 
4.3.3
S.M.A.R.T. commands
S.M.A.R.T. provides near-term failure prediction for disc drives. When S.M.A.R.T. is enabled, the drive monitors 
predetermined drive attributes that are susceptible to degradation over time. If self-monitoring determines that a 
failure is likely, S.M.A.R.T. makes a status report available to the host. Not all failures are predictable. S.M.A.R.T. 
predictability is limited to the attributes the drive can monitor. For more information on S.M.A.R.T. commands and 
implementation, see the Draft ATA-8 Standard.
SeaTools diagnostic software activates a built-in drive self-test (DST S.M.A.R.T. command for D4
H
) that eliminates 
unnecessary drive returns. The diagnostic software ships with all new drives and is also available at: 
.
This drive is shipped with S.M.A.R.T. features disabled. You must have a recent BIOS or software package that 
supports S.M.A.R.T. to enable this feature. The table below shows the S.M.A.R.T. command codes that the drive 
uses.
Note.
If an appropriate code is not written to the Features Register, the command is aborted and 004 (abort) 
is written to the Error register.
82
H
Disable write cache
86
H
Disable PUIS feature set
AA
H
Enable read look-ahead (read cache) feature (default).
F1
H
Report full capacity available
Table 9: 
S.M.A.R.T. commands
Code in features register
S.M.A.R.T. command
D0
H
S.M.A.R.T. Read Data
D1
H
Vendor-specific
D2
H
S.M.A.R.T. Enable/Disable Attribute Autosave
D3
H
S.M.A.R.T. Save Attribute Values
D4
H
S.M.A.R.T. Execute Off-line Immediate (runs DST)
D5
H
S.M.A.R.T. Read Log Sector
D6
H
S.M.A.R.T. Write Log Sector
D7
H
Vendor-specific
D8
H
S.M.A.R.T. Enable Operations
D9
H
S.M.A.R.T. Disable Operations
DA
H
S.M.A.R.T. Return Status
Table 8: 
Set Features command values