Seagate ST32430WD ユーザーズマニュアル

ページ / 40
Hawk 2LP (Wide) Installation Guide, Rev. A           29
continued from previous page
DS ME
Off Off
Spindle starts immediately after power up -
Default setting.
Off On
Drive spindle does not start until Start Unit
command received from host.
On Off
Spindle Start-up is delayed by SCSI ID times
12 seconds after power is applied, i.e., drive
0 spindle starts immediately when DC power
connected, drive 1 starts after 12 second
delay, drive 2 starts after 24 second delay,
etc.
On On
Drive spindle starts when Start Unit com-
mand received from host. Delayed start fea-
ture is overridden and does not apply when
ME jumper is installed.
WP
On
Entire drive is write protected.
Off
Drive is not write protected. Default is no WP
jumper installed.
PE
On
Parity checking and parity error reporting by
the drive is enabled. Default is PE jumper
installed.
Off
Drive does not report result of parity check-
ing to host.