Seagate ST900MM0036 ユーザーズマニュアル

ページ / 84
Savvio 10K.4 FC Product Manual, Rev. A
53
9.3.1
Inquiry data
Table 16 lists the Inquiry command data that the drive should return to the initiator per the format given in the 
Fibre Channel Interface Manual.  
*
Copyright year (changes with actual year).
**
SCSI Revision support. Refer to the appropiate SPC release documentation for definitions.
PP
50 = Inquiry data for an Inquiry command received on Port A.
70 = Inquiry data for an Inquiry command received on Port B.
R#
Four ASCII digits representing the last four digits of the product firmware release number.
S#
Eight ASCII digits representing the eight digits of the product serial number.
[ ]
Bytes 16 through 26 reflect model of drive. The table above shows the hex values for model ST9600204FC.
Bytes 16 through 26 values for other models are shown below:
ST9450404FC
53 54 39 34 35 30 34 30 34 46 43
ST9600204FC
53 54 39 36 30 30 32 30 34 46 43
9.3.2
Mode Sense data 
The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The 
drive maintains four sets of mode parameters:
1.
Default values
Default values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the 
drive’s PCB. These default values can be changed only by downloading a complete set of new firmware 
into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use 
those in a Mode Select command to set up new current and saved values, where the values are change-
able.
2.
Saved values
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that 
are allowed to be changed can be changed by this method. Parameters in the saved values list that are not 
changeable by the Mode Select command get their values from default values storage.
When power is applied to the drive, it takes saved values from the media and stores them as current val-
ues in volatile memory. It is not possible to change the current values (or the saved values) with a Mode 
Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a 
“Check Condition” status.
On drives requiring unique saved values, the required unique saved values are stored into the saved val-
ues storage location on the media prior to shipping the drive. Some drives may have unique firmware with 
unique default values also.
Table 16: 
Savvio 10K.4 FC inquiry data
Bytes
Data (hex)
0-15
00
00
xx**
12
8B
00
PP
02
53
45
41
47
41
54
45
20
Vendor ID
16-31
[53
54
39
36
30
30
32
30
34
46
43]
1
20
20
20
20
20
Product ID
32-47
R#
R#
R#
R#
S#
S#
S#
S#
S#
S#
S#
S#
00
00
00
00
48-63
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
64-79
00 00 00  00 00 00 00 00 00 00 00  00 00 00 00 00
80-95
00 00 00  00
00 00 00 00 00 00 00  00 00 00 00 00
96-111
00 43 6F  70 
 79 72 69 67 68 74 20  28 63 29 20 32*
*Copyright
112-127
30*
30*
39*
20
53 65 61 67 61 74
65
20
41
6C
6C
20
notice
128-143
72 69 67  68
74 73 20 72 65 73 65  72 76 65 64 20