Seagate ST3500320SV ユーザーズマニュアル

ページ / 54
SV35.3 Series Serial ATA Product Manual, Rev. B
33
4.3.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following 
power up. The data is organized as a single 512-byte block of data, whose contents are shown in Table 7 on 
page 30. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or 
vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.
The following commands contain drive-specific features that may not be included in the Serial ATA specifica-
tion.
Word
Description
Value
 
 
0
Configuration information:
 
• Bit 15: 0 = ATA; 1 = ATAPI
 
• Bit 7: removable media
 
• Bit 6: removable controller
 
• Bit 0: reserved
0C5A
H
1
Number of logical cylinders
16,383
2
ATA-reserved
0000
H
3
Number of logical heads
16
4
Retired
0000
H
5
Retired
0000
H
6
Number of logical sectors per logical track: 63
003F
H
7–9
Retired
0000
H
10–19
Serial number: (20 ASCII characters, 0000
H
 = none)
ASCII
20
Retired
0000
H
21
Retired
0400
H
22
Obsolete
0000
H
23–26
Firmware revision (8 ASCII character string, padded with blanks to 
end of string)
x.xx
27–46
Drive model number: (40 ASCII characters, padded with blanks to end 
of string)
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and Write 
multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY supported and may be disabled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle  timing mode
0200
H
52
Retired
0200
H