Seagate ST318405LW/LC ユーザーズマニュアル

ページ / 96
Cheetah 36XL Product Manual, Rev. E
31
The maximum allowable HDA case temperature is 140°F (60°C). Operation of the drive at the maximum
case temperature is intended for short time periods only. Continuous operation at the elevated temperatures
will reduce product reliability.
Figure 12.
Location of HDA Temperature Check Point
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This
specification assumes that the drive is packaged in the shipping container designed by Seagate for use with
drive.      
6.4.2
Relative humidity
The values below assume that no condensation on the drive occurs.
a. Operating
5% to 95% non-condensing relative humidity with a maximum gradient of 10% per hour.
b. Non-operating
5% to 95% non-condensing relative humidity.
6.4.3
Effective altitude (sea level)
a. Operating
–1000 to +10,000 feet (–305 to +3,048 meters)
b. Non-operating
–1000 to +40,000 feet (–305 to +12,195 meters)
6.4.4
Shock and vibration
Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is
installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur
internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent,
it may be necessary to modify the enclosure to minimize drive movement.
The limits of shock and vibration defined within this document are specified with the drive mounted by any of
the four methods shown in Figure 13, and in accordance with the restrictions of Section 8.4. Orientation of the
side nearest the J6 may be up or down.
6.4.4.1
Shock
a. Operating—normal
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not
exceeding 15.0 Gs at a maximum duration of 11 msec (half sinewave). Shock may be applied in the X, Y, or
Z axis.
HDA Temp.
Check Point
.5"