Seagate ST320LT011 - 9ZVG42 ユーザーズマニュアル

ページ / 46
10
Momentus Thin Product Manual, Rev. C Gen-2
3.9.1.1
Typical current profile
Figure 1. Typical +5V only startup and operation current profile
3.9.2
Deferred spinup
Momentus Thin drives do not support the deferred spinup option. If you require this option, refer to the Momen-
tus 5400.3 SATA Blade Server family of drives.
3.9.3
Conducted noise
Input noise ripple is measured at the host system power supply across an equivalent 15-ohm resistive load on 
the +5 volt line.
Using 5-volt power, the drive is expected to operate with a maximum of 100 mV peak-to-peak square-wave 
injected noise at up to 10 MHz.
Note.
Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write 
current.
3.9.4
Voltage tolerance
Voltage tolerance (including noise):
5V ± 10%