Seagate ST3500071FC ユーザーズマニュアル

ページ / 88
26
NL35 Series FC Product Manual, Rev. D
[5]
See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and 
transient response.
[6]
Operating condition is defined as random 8 block reads at 161 I/Os per second.
 
Current and power specified at nominal voltages. Decreasing +5 volt supply by 5% increases 5 volt cur-
rent by
 
<0.5%. Decreasing +12 volt supply by 5% increases 12 volt current by 1.4%.
[7]
During idle, the drive heads are relocated every 60 seconds to a random location within the band from 
track zero to one-fourth of maximum track.
General DC power requirement notes.
1.
Minimum current loading for each supply voltage is not less than 1.2% of the maximum operating current 
shown. 
2.
The +5V and +12V supplies should employ separate ground returns. 
3.
Where power is provided to multiple drives from a common supply, careful consideration for individual 
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak 
starting current must be available to each device.
4.
Parameters, other than spindle start, are measured after a 10-minute warm up.
5.
No terminator power.
6.2.1
Conducted noise immunity 
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 20 MHz. 
Maximum allowed noise values given below are peak to peak measurements and apply at the drive power con-
nector.
6.2.2
Power sequencing 
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up 
and down.
  +5 V =
250 mV pp from 10 Hz to 10 MHz.
 
250 mV pp from 10 MHz to 20 MHz.
+12 V =
400 mV pp from 10 Hz to 100 Hz.
 
800 mV pp from 100 Hz to 8 KHz.
 
450 mV pp from 8 KHz to 20 KHz.
 
400 mV pp from 20 KHz to 10 MHz.
 
250 mV pp from 10 KHz to 20 MHz.