Seagate ST3500071FC ユーザーズマニュアル

ページ / 88
40
NL35 Series FC Product Manual, Rev. D
8.3
Cooling 
The host enclosure must provide heat removal from the drive. You should confirm that the host enclosure is 
designed to ensure that the drive operates within the temperature measurement guidelines described in Sec-
tion 6.4.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures 
specified in Section 6.4.1.
If forced air is necessary, possible air-flow patterns are shown in Figure 7. The air-flow patterns are created by 
fans either forcing or drawing air as shown in the illustrations. Conduction, convection, or other forced air-flow 
patterns are acceptable as long as the temperature measurement guidelines of Section 6.4.1 are met.   
Figure 7.
 Air flow
Above unit
Under unit
Note.  Air flows in the direction shown (back to front)
           or in reverse direction (front to back)
Above unit
Under unit
Note.  Air flows in the direction shown or
           in reverse direction (side to side)