Seagate ST3500620SS ユーザーズマニュアル

ページ / 82
12
Barracuda ES.2 SAS Product Manual, Rev. E
4.2.2
Format command execution time (minutes) 
ST31000640SS
ST3750630SS
ST3500620SS
Maximum (with verify)
400
300
200
Maximum (without verify)
200
150
100
Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request 
for a Status Byte Transfer to the Initiator (excluding connect/disconnect).
4.2.3
General performance characteristics
Sustainable disk transfer rate*:
Minimum
56 Mbytes/sec
Maximum
116 Mbytes/sec
SAS Interface maximum instantaneous transfer rate
300 Mbytes/sec* per port 
(dual port = 600 Mbytes/sec*)
Logical block sizes
Default is 512-byte data blocks
 
Sector sizes variable to 512, 520, 524, and 528 kbytes.
Read/write consecutive sectors on a track
Yes
Flaw reallocation performance impact (for flaws reallocated at format time using
 
the spare sectors per sparing zone reallocation scheme.)
Negligible
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host.
4.3
Start/stop time
The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has 
been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START 
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 20 
seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY 
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1. 
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY 
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the 
drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does 
not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT 
command.
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 sec-
onds (maximum) from removal of DC power.
There is no power control switch on the drive.