Barracuda ES.2 SAS Product Manual, Rev. E
 
 
[1] Measured with average reading DC ammeter or equivalent sampling scope. Instantaneous +12V current 
peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 
Degrees C ambient.
[2] For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 
7,200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been 
completed and that the drive is able to accept selection by the host initiator. 
[3] See +12V current profile in Figure 2.
Table 3: 
ST3750630SS 
DC power requirements
Notes
ST3750630SS
 
3 Gbit mode
(Amps)
(Amps)
Voltage
+5V
+12V [2]
Regulation
[5]
±5%
±5% [2]
Avg idle current DCX
0.60
0.50
Maximum starting current
(peak DC) DC
3
σ
0.90
2.00
(peak AC) AC
3
σ
1.10
3.50
Delayed motor start (max) DC 3
σ
0.60
0.17
Peak operating current:
     Typical DCX
0.62
0.78
     Maximum DC
3
σ
0.74
0.82
     Maximum (peak) DC
3
σ
1.15
1.75
Table 4: 
ST3500620SS 
DC power requirements
Notes
3 Gbit mode
(Amps)
(Amps)
Voltage
+5V
Regulation
[5]
±5%
±5% [2]
Avg idle current DCX
[1] [6]
0.60
0.50
Maximum starting current
(peak DC) DC
3
σ
[3]
0.90
2.00
(peak AC) AC
3
σ
[3]
1.10
3.50
Delayed motor start (max) DC 3
σ
0.60
0.17
Peak operating current:
     Typical DCX
[1]
0.62
0.78
     Maximum DC
3
σ
[1]
0.74
0.82
     Maximum (peak) DC
3
σ
1.15
1.75