Seagate ST9120410ASG ユーザーズマニュアル

ページ / 44
14
Momentus 7200.4 SATA Product Manual, Rev. C
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
2.13
Reliability 
Measurement type
Specification
Nonrecoverable read errors
1 per 10
14
 bits read, max.
Annualized Failure Rate (AFR)
0.5%
Load/Unload (U/UL)
 
 
25°C, 50% relative humidity
 
 
 
32°C, 80% relative humidity 
 
5°C, 80% relative humidity 
 
5°C, 10% relative humidity 
 
55°C, 16% relative humidity 
 
 
600,000 software-controlled power on/off cycles
 
50,000 hard power on/off cycles
 
 
600,000 software-controlled power on/off cycles
 
50,000 hard power on/off cycles
 
 
Warranty
For information regarding Warranty Support, visit 
 
http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance
 
2.13.1
Free Fall Protection feature
The Free Fall Protection feature provides enhanced data protection against shock events that may occur while 
the drive is operating. This feature is designed to decrease the likelihood of data loss by detecting a free fall 
event and unloading the actuator before a shock takes place in falls of >8 inches (nominal). The drive uses a 
0G sensor mounted on the printed circuit board assembly (PCBA) to sense this event.
To enable the Free Fall Protection feature on ST9500420ASG, ST9320423ASG, ST9250410ASG, 
ST9160412ASG, ST9120410ASG and ST980412ASG models, use Set Features command 41h. To disable 
this feature, use Set Features command C1h.
Information about Free Fall Events that have occurred is available through SMART Attribute FEh.
Note.
The Free Fall Protection feature is provided only on ST9500420ASG, ST9320423ASG, 
ST9250410ASG, ST9160412ASG, ST9120410ASG and ST980412ASG models.
Table 6: 
Radio frequency environments
Test
Description
Performance 
level
Reference 
standard
Electrostatic discharge
Contact, HCP, VCP: 
± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz 
sine
A
EN 61000-4-6: 97
Power Frequency H-field 
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
 
>95% Reduction for 250 cycles
 
>95%, 0.5 cycles
C
 
C
 
B
EN 61000-4-11: 94