Seagate ST3300602FC ユーザーズマニュアル

ページ / 90
Cheetah NS 10K.2 FC Product Manual, Rev. B
47
9.0
Interface requirements 
This section partially describes the interface requirements as implemented on Cheetah NS 10K.2 FC drives. 
Additional information is provided in the Fibre Channel Interface Manual (part number 100293070).
9.1
FC-AL features
This section lists the Fibre Channel-specific features supported by Cheetah NS 10K.2 FC drives.
9.1.1
Fibre Channel link service frames
Table 6 lists the link services supported by Cheetah NS 10K.2 FC drives.
Table 6:
Link services supported
Type of frame
Link service
Basic link service frames
Abort Sequence (ABTS)
Basic link service reply frames
Basic_Accept (BA_ACC)
 
Basic_Reject (BA_RJT)
Extended link service frames
N_Port Login (PLOGI)
Fabric Login (FLOGI)
 
Logout (LOGO)
 
Process Login (PRLI)
 
Process Logout (PRLO)
 
Read Link Status (RLS)
Fabric Address Notification (FAN)
 
Port Discovery (PDISC)
 
Address Discovery (ADISC)
Third-party Process Logout (TRPLO)
Extended link service reply frames
Accept (ACC)
 
Link Service Reject (LS_RJT)
Fibre Channel Services
Register FC-4 Types (RFT_ID)