General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current 
shown. 
2. The +5V and +12V supplies should employ separate ground returns. 
3. Where power is provided to multiple drives from a common supply, careful consideration for individual 
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak 
starting current must be available to each device.
4. Parameters, other than spindle start, are measured after a 10-minute warm up.
5. No terminator power.
7.3.1
Conducted noise immunity 
Noise is specified as a periodic and random distribution of frequencies covering a defined frequency range.
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power 
connector. 
7.3.2
Power sequencing 
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up 
and down.
+5v
=
250mVpp from 100Hz to 20MHz.
+12v
=
450mVpp from 100Hz to 100KHz. 
250mVpp from 100KHz to 20MHz. 