Seagate ST336918N ユーザーズマニュアル

ページ / 96
22
Barracuda 36ES2 Product Manual, Rev. B
6.2.1
Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz.
Maximum allowed noise values given below are peak to peak measurements and apply at the drive power con-
nector.
6.2.2
Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up
and down. Daisy-chain operation requires that power be maintained on the SCSI bus terminator to ensure
proper termination of the peripheral I/O cables. To automatically delay motor start based on the target ID (SCSI
ID) enable the Delay Motor Start option and disable the Enable Motor Start option on the J2 connector. See
Section 8.1 for pin selection information. To delay the motor until the drive receives a Start Unit command,
enable the Enable Remote Motor Start option on the J2 connector.
6.2.3
12 V - Current profile
Figure 2 identifies the drive +12 V current profiles. The current during the various times is as shown:
Note.
All times and currents are typical. See Table 2 for maximum current requirements. 
Figure 2.
Typical ST336938/ST336918/ST318438/ST318418 drive +12 V current profile
+5 V =
150 mV pp from 0 to 100 kHz and 100 mV pp from 100 kHz to 10 MHz
+12 V =
150 mV pp from 0 to 100 kHz and 100 mV pp from 100 kHz to 10 MHz
T0 -
Power is applied to the drive.
T1 -
Controller self tests are performed.
T2 -
Spindle begins to accelerate under current limiting after performing drive internal 
diagnostics. See Note 1 of Table 2.
T3 -
The spindle is up to speed and the head-arm restraint is unlocked.
T4 -
The adaptive servo calibration sequence is performed.
T5 -
Calibration is complete and drive is ready for reading and writing.
0.0
2
4
6
8
10
12
14
16
0.0
0.5
1.0
1.5
2.0
2.5
A
Seconds
T0
AC Envelope
+12 Volt Current during spindle start — Typical Amperes
DC average of waveform