Fujitsu MAC3045 ユーザーズマニュアル

ページ / 142
C141-E035-02EN
5 - 7
5.3.1
SCSI ID setting
(1)
SCA type 16-bit SCSI model (MAx3xxxSC)
There is no SCSI ID setting terminal for SCA type model. Set the SCSI ID using ID0, ID1,
ID2, and ID3 signals on the SCSI interface connector (CN1).
(2)
Single-ended 16-bit SCSI model (MAx3xxxSP)
Table 5.1 shows the SCSI ID setting. Refer to Figures 5.2 and 5.3 for connector positioning
and allocation.
IMPORTANT
When the SCSI ID is set using the external operator panel
connector CN1, all pins listed in Table 5.1 should be open.  If any
of pins are shorted, unexpected SCSI ID is set.
Table 5.1
SCSI ID setting (single-ended 16-bit SCSI model: MAx3xxxSP)
SCSI ID
MAx3xxxSP (CN7)
5-6
3-4
1-2
5-6
0
Open
Open
Open
Open
1
Open
Open
Open
Short
2
Open
Open
Short
Open
3
Open
Open
Short
Short
4
Open
Short
Open
Open
5
Open
Short
Open
Short
6
Open
Short
Short
Open
7
Open
Short
Short
Short
8
Short
Open
Open
Open
9
Short
Open
Open
Short
10
Short
Open
Short
Open
11
Short
Open
Short
Short
12
Short
Short
Open
Open
13
Short
Short
Open
Short
14
Short
Short
Short
Open
15 (*1)
Short
Short
Short
Short
*1  Set at factory shipment