Toshiba 4006GAH ユーザーズマニュアル

ページ / 157
360050398 
 
Toshiba Corporation Digital Media Network Company 
 
Page 82 of 157 
© 2005, Copyright TOSHIBA Corporation All Rights Reserved 
 
 
Table 10.8-4    Identify Information (Continued) 
WORD  
 DESCRIPTION   
Hex. 
87 
Command set/feature default 
   15    0 (Fixed) 
   14    1 (Fixed) 
   13    1 (Fixed) 
 12-6    Reserved 
    5    1=General Purpose Logging feature set supported 
        4        Reserved 
    3    1=Media Card Pass Through Command feature set enabled 
    2    1=Madia serial number is valid 
    1    1=SMART self-test supported 
 
6023 
88 
 15-8    Ultra DMA transfer mode selected 
  7-0    Ultra DMA transfer modes supported    
XX3F 
89 
Time required for security erase unit completion 
00XX 
90 
Time required for Enhanced Security erase completion 
0000 
91 
Current Advanced Power Management setting 
 15-8 Reserved 
7-0 Current Advanced Power Management setting set by Set Features 
Command 
00XX 
92 
Master Password Revision Code     
XXXX 
93 
Hardware reset result. The conetnts of bits 12-0 of this word shall change only 
during the execution of a hardware reset.   
15 0 
(Fixed) 
14    1 (Fixed) 
     13    1=device detected CBLID- above V
IH
 
       0=device detected CBLID- below V
IL
 
12-8 
Device 1 hardware reset result. Device 0 shall clear these bits to 
zero. 
Device 1 shall set these bits as follows : 
12 Reserved. 
11 
0=Device 1 did not assert PDIAG-. 
1=Device 1 asserted PDIAG-. 
10-9 
These bits indicate how Device 1 determined the device 
number: 
00=Reserved. 
01=a jumper was used. 
10=the CSEL signal was used. 
11=some other method was used or the method is 
unknown. 
8 1 
(Fixed) 
7-0 
Device 0 hardware reset result. Device 1 shall clear these bit to 
zero. 
Device 0 shall set these bills as follows: 
7 Reserved. 
0=Device 0 does not respond when Device 1 is selected. 
1=Device 0 responds when Device 1 is selected. 
0=Device 0 did not detect the assertion of DASP-. 
1=Device 0 detected the assertion of DASP-. 
0=Device 0 did not detect the assertion of PDIAG-. 
1=Device 0 detected the assertion of PDIAG-.   
0=Device 0 failed diagnostics. 
1=Device 0 passed diagnostics. 
2-1 
These bits indicate how Device 0 determined the device 
number: 
00=Reserved. 
01=a jumper was used. 
10=the CSEL signa was used. 
11=some other method was used or the method is 
unknown. 
 0     1 (Fixed) 
XXXX 
94 
Current automatic acoustic management value 
 15-8    Vendor’s recommended acoustic management value 
  7-0    Current automatic acoustic management value 
0000 
95-99 Reserved 
0000 
100-103 
Maximum user LBA for 48-bit Address feature set 
XXXX 
104-126 Reserved 
0000