Emerson MVME2500 ユーザーズマニュアル
Hardware Preparation and Installation
MVME2500 Installation and Use (6806800L01H)
27
2.3.1
Environmental Requirements
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
not to the component temperature.
Table 2-1 Environmental Requirements
Characteristics
Commercial Versions
Extended Temperature Versions
Applicable Variants
MVME2500-0163
MVME2500-0161
MVME2500-0173
MVME2500-0171
MVME2500-0161
MVME2500-0173
MVME2500-0171
MVME2500ET-0173
MVME2500ET-0171
MVME2500ET-0171
Cooling Method
Forced Air 7 CFM
1
Forced Air 7 CFM
1
Operating
Temperature
Temperature
0°C to +55°C
-40°C to +71°C
Storage
-40°C to +85°C
-50°C to +100°C
Vibration Sine
(10min/axis)
(10min/axis)
2 G, 5 to 2000 Hz
10 G, 15 to 2000 Hz
Vibration Random
(1hr/axis)
(1hr/axis)
0.01g2/Hz, 15 to 2000 Hz
0.04g2/Hz, 15 to 2000 Hz (8
GRMS)
GRMS)
2
Shock
20g/11 mS
30g/11 mS
Humidity
to 95% RH (non-condensing)
to 100% RH (non-condensing)
1. ft3/min
2. Flat 15-1000Hz, -6db/octave 1000Hz - 2000Hz [MIL-STD 810F Figure 514.5C-17]