AMCC 720-0138-00 ユーザーズマニュアル

ページ / 170
Error and Notification Messages
www.3ware.com 
117
Error and Notification Message Details
0001 Controller reset occurred
The 3ware RAID controller has detected a soft reset from the device driver. If 
the 3ware RAID controller fails to respond to the device driver within a 
reasonable amount of time, the device driver may issue a soft reset to the 
3ware RAID controller and retry the command packet. For more information, 
see 
http://www.3ware.com/KB/article.aspx?id=14923.
0002 Degraded unit
An error has been encountered and the unit is operating in degraded (non-
redundant) mode. You should replace the bad drive as soon as possible and 
initiate a rebuild.
Removing a drive from a redundant unit will cause this message to display 
immediately.
0003 Controller error occurred
The 3ware RAID controller has encountered an internal error. Please contact 
AMCC Customer Support as a replacement board may be required. 
0004 Rebuild failed
The 3ware RAID controller was unable to complete a rebuild operation. This 
error can be caused by drive errors on either the source or the destination of 
the rebuild. However, due to ATA drives’ ability to reallocate sectors on write 
errors, the rebuild failure is most likely caused by the source drive of the 
rebuild detecting some sort of read error. The default operation of the 3ware 
RAID controller is to abort a rebuild if an error is encountered. If it is desired 
to continue on error, you can set the Continue on Source Error During Rebuild 
policy for the unit on the Controller Settings page in 3DM.
0005 Rebuild completed
The 3ware RAID controller has successfully completed a rebuild. The 
completion of the rebuild changes the state of the unit from rebuilding to OK. 
The data is now redundant.