Black Box LPJ016A-TM ユーザーズマニュアル

ページ / 43
724-746-5500   |   blackbox.com 
724-746-5500   |   blackbox.com 
Page 39
Appendix B: SNMP MIB Controls
 
Table B-1 (Continued). SNMP MIB.
  OID 
Name 
Type 
Value 
Description
  2.3.6.1.24852.2.2.14.0 
poeSystemControlDCPower*** 
INTEGER 
Read-write 
 This attribute is cleared 
through the powerPort-
CurrentStatusClear action.
  2.3.6.1.4.1.24852.2.3.1.5.0  poePortCurrentStatusClear*** 
INTEGER 
off(1) 
Setting the value of this 
     
 
 
clear(2) 
 object to clear(2) clears 
the value of the poePort-
Status and enables the 
agent to update the poe-
PortStatus. During Read 
operation, this value will 
be off(1).
  2.3.6.1.4.1.24852.2.3.1.6.1~24 poePortDescription 
DisplayString 
Read-write 
Describes the port. 
     
 
(SIZE (0..10))
  2.3.6.1.4.1.24852.2.3.1.7.1~24  poePortDetectionStatus*** 
INTEGER 
Read-only 
Off(0) 
     
 
 
 
DiscR(1) 
     
 
 
 
DiscC(3) 
     
 
 
 
RampUp(4) 
     
 
 
 
RampDown(5) 
     
 
 
 
SampleI(8) 
     
 
 
 
SampleV(9)
  2.3.6.1.4.1.24852.2.3.1.8.1~24  poePortPowerClassifications*** 
INTEGER 
Read-only 
Class0(1) 
     
 
 
 
Class1(2) 
     
 
 
 
Class2(3) 
     
 
 
 
Class3(4) 
     
 
 
 
Class4(5)
  2.3.6.1.4.1.24852.2.3.1.9.1~24  poePortPowerDetectionControl***  INTEGER 
Read-write 
 Controls the port power 
detection control.
  2.3.6.1.4.1.24852.2.3.1.10.1~24 poePortPowerPriority*** 
INTEGER 
Critical(1) 
Sets port priority. 
     
 
 
High(2) 
     
 
 
Low(3) 
  2.3.6.1.4.1.24852.2.3.1.11.1~24  poePortPower 
INTEGER 
Read-only 
 Port power reading (in 
mWatts).
  2.3.6.1.4.1.24852.2.3.1.12.1~24 poePortVoltage 
INTEGER 
Read-only 
 Port voltage reading (in 
volts).
  2.3.6.1.4.1.24852.2.3.1.13.1~24  poePortCurrent 
INTEGER 
Read-only 
 Port current reading (in 
mAmps).
  2.3.6.1.4.1.24852.2.3.1.14.1~24  poePortResistance 
INTEGER 
Read-only 
 Port resistance reading (in 
ohms).
*** Currently disabled. Reserved for future use.