Micro Star Computer G31M ユーザーズマニュアル

ページ / 116
M S-7379  M ainboard
C-22
A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard
drive members fails or is temporarily disconnected, and data mirroring is lost. As a
result, the system can only utilize theremaining functional hard drive member. To re-
establish data  mirroring and restore data redundancy, refer to the  procedure below
that corresponds to the current situation.
Missing Hard Drive Member
1.  Make sure the system  is powered off.
2. Reconnect the hard drive.
3. Reboot the system to W indows; the rebuild will occur automatically.
Failed Hard Drive Member
1.  Make sure the system  is powered off.
2.  Replace  the  failed  hard  drive  with  a  new  one  that  is  of  equal  or  greater
capacity.
3. Reboot the system to Intel RAID Option ROM by press <Ctrl> and <I> keys
simultaneously during the Power-On Self Test (POST).
Degraded RAID Array
4. Select the port of the destination disk for rebuilding, and then press ENTER.