Cypress CY7C1034DV33 ユーザーズマニュアル

ページ / 9
CY7C1034DV33
Document Number: 001-08351 Rev. *C
 Page 4 of 9 
Figure 2.  AC Test Loads and Waveform
AC Switching Characteristics 
Over the operating range 
Parameter
Description
–10
Unit
Min
Max
Read Cycle
t
power
V
CC
(Typical) to the First Access
100
μs
t
RC
Read Cycle Time
10
ns
t
AA
Address to Data Valid
10
ns
t
OHA
Data Hold from Address Change
3
ns
t
ACE
CE
 
Active LOW to Data Valid
10
ns
t
DOE
OE LOW to Data Valid
5
ns
t
LZOE
OE LOW to Low Z
1
ns
t
HZOE
OE HIGH to High Z
5
ns
t
LZCE
CE
 
Active LOW to Low Z
3
ns
t
HZCE
CE Deselect
 
HIGH to High Z
5
ns
t
PU
CE
 
Active LOW to Power Up
0
ns
t
PD
CE Deselect
 
HIGH to Power Down 
10
ns
90%
10%
3.0V
GND
90%
10%
All input pulses
3.3V
OUTPUT
5 pF*
(a)
(b)
R1 317
Ω
R2
351
Ω
Fall Time:> 1V/ns
(c)
OUTPUT
50
Ω 
Z0= 50Ω
V
TH
= 1.5V
30 pF*
*Capacitive Load consists of all
components of the test environment
Rise Time > 1V/ns
*Including jig 
and scope
Notes
4. Valid SRAM operation does not occur until the power supplies reach the minimum operating V
DD
 (3.0V). 100 
μs (t
power
) after reaching the minimum operating V
DD
normal SRAM operation begins including reduction in V
DD
 to the data retention (V
CCDR
, 2.0V) voltage.
5. Test conditions assume signal transition time of 3 ns or less, timing reference levels of 1.5V, and input pulse levels of 0 to 3.0V. Test conditions for the read cycle use 
output loading as shown in part a) of the 
, unless specified otherwise.
6. t
POWER
 gives the minimum amount of time that the power supply is at typical V
CC
 values until the first memory access is performed.
7. t
HZOE
, t
HZCE
, t
HZWE
, t
LZOE
, t
LZCE
, and t
LZWE
 are specified with a load capacitance of 5 pF as in part (b) of AC Test Loads. Transition is measured 
±200 mV from steady 
state voltage.
8. These parameters are guaranteed by design and are not tested.