IBM 81Y ユーザーズマニュアル

ページ / 226
 
 Diagnostics
 19
ServeRAID ISPR, BCS, and ECS POST error 
codes
After the ServeRAID POST completes, register information appears on the screen in 
hexadecimal format, as follows: 
   Hardware:  ISPR=aaaa  BCS=bb  ECS=cc
ISPR displays the four-digit Interrupt Status Report Register code, BCS displays the 
Basic Configuration Status Register code, and ECS displays the Extended 
Configuration Status Register code.
For example: 
Controller 1 Slot 5, Status:Not responding properly - Error Code=0B0
Controller 2 Slot 4, Logical Drive=0, Other=0, Firmware=2.88.10, Status=Ok
Controller 3 Slot 3, Logical Drive=0, Other=0, Firmware=3.60.13, Status=Ok
Controller 4 Slot 2, Logical Drive=1, Other=1, Firmware=1.00.09, Status=Ok
If no errors occur:
ISPR (aaaa) = EF10
BCS (bb) = 0F or 09
ECS (cc) = 00
If an error occurs, refer to: “ServeRAID POST (ISPR) error codes” on page 161 for the 
ISPR error codes and “Basic and Extended Configuration Status Register Codes” on 
page 20 fo
r the BCS and ECS error codes.
Unrecoverable configuration error.
Explanation:  
The configuration data stored in NVRAM does not match the configuration 
data stored in the EEPROM.
Action:  
1.
Press Ctrl+I to access the ServeRAID Mini-Configuration menu.
2.
Select Advanced Functions from the Main Menu.
3.
Select Restore to the Factory Default Settings.  
WARNING:  n logical drives are critical; n logical drives are offline.
Explanation:  
One or more physical drives have failed.
Action:  
Replace the defunct drives as soon as possible to prevent data loss.
Your server has an error due to a Blocked Logical Drive.
Explanation:  
One or more logical drives are blocked.  A blocked logical drive cannot be 
accessed.
Action:  
Press F4 to unblock the logical drive, or press F5 to continue without unblocking.