3. Installation
RuggedCom® RuggedBackbone™
18
RX1501 Installation Guide Rev 104
3. Installation
3.1. Rack Mounting
The RuggedBackbone™ RX1501 mounts to a standard 19" rack. Rack mounting brackets can be
installed at the front or rear of the chassis. Placing the connectors at the rear allows all data and
power cabling to be installed and connected on the same side of the rack.
Remove the black pan head Phillips screws from the front or rear mounting locations. Position
the rack mounting bracket, aligning the holes in the bracket with the screw holes on the chassis.
Attach the mounting bracket with the screws from the chassis. Torque all screws to 10 in-lbs.
For high-vibration or seismically active locations, use rack mounting brackets at all four corners
of the chassis.
Due to the heat dissipated in the RX1501 chassis, it is recommended that 1 unit of rack
space (1U or 1.75") be left unpopulated and free of equipment above each RX1501 unit
to allow for convection airflow. Although forced airflow is not necessary, any increase
in airflow will result in a reduction of ambient temperature and will improve long-term
reliability of all equipment mounted in the rack.
REAR MOUNTING BRACKET
FRONT MOUNTING BRACKET
Figure 3.1. Side View of Mounting Brackets
3.1.1. Rack Mounting Dimensions
Figure 3.2. RX1501Rack Mounting Dimensions – Front View