Samsung C8278X ユーザーズマニュアル

ページ / 324
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X  
 
ELECTRICAL 
DATA 
 
17-9 
Table 17-6. Battery Level Detector Electrical Characteristics 
(T
A
   
=  25
°
C,  V
DD
 = 2.0 V  to  3.6 V) 
Parameter Symbol 
Conditions Min 
Typ 
Max 
Unit 
Operating voltage of BLD 
V
DDBLD
 
− 
2.0 
− 
3.6 V 
Voltage of BLD 
V
BLD
 
BLDCON.2-.0 = 000b 
2.0 
2.2 
2.4 
 
 
 
BLDCON.2-.0 = 101b 
2.15 
2.4 
2.65 
 
 
 
BLDCON.2-.0 = 011b 
2.5 
2.8 
3.1 
 
Current consumption 
I
BLD
 
V
DD
 = 3.3 V 
− 
70 120 
µA 
 
 
V
DD
 = 2.2 V 
− 
50 100   
Hysteresis voltage of BLD 
∆V 
BLDCON.2-0 = 000b, 
101b, 011b 
− 
10 100 mV 
BLD circuit response time 
T
B
 
Fw = 32.768 kHz 
− 
− 
1 ms 
 
Table 17-7. LVR (Low Voltage Reset) Electrical Characteristics 
(T
A
   
=  25
°
C) 
Parameter Symbol 
Conditions Min 
Typ 
Max 
Unit 
Voltage of LVR 
V
LVR
 
T
A
 = 25 
°
2.0 2.2 2.4  V 
V
DD
 voltage rising time 
t
R
 
− 
10 
− 
− 
µs 
V
DD
 voltage off time 
t
OFF
 
− 
0.5 
− 
− 
Hysteresis voltage of LVR 
∆V 
− 
− 
10 100 mV 
Current consumption 
I
DDPR
 
V
DD
 = 3.3 V 
− 
70 120 
µA 
NOTES: 
1.  The current of LVR circuit is consumed when LVR is enabled by "Smart Option" 
2.  Current consumed when low voltage reset circuit is provided internally. 
 
t
R
t
OFF
0.9 V
DD
0.1 V
DD
V
DD
 
Figure 17-6. LVR (Low Voltage Reset) Timing