CPUs for M7-400
11-42
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
Interrupt Assignment
Table 11-9 Interrupt Assignment
Interrupt
Function
NMI
Group interrupt for faults and reset signals
IRQ0
System timer
IRQ1
Reserved for keyboard
IRQ2
Cascading of the 2nd interrupt controller
IRQ3
Assigned to COM2, otherwise free
IRQ4
Assigned to COM1, otherwise free
IRQ5
Assigned to LPT2, otherwise free
IRQ6
Assigned to floppy disk drive, otherwise free
IRQ7
Assigned to LPT1, otherwise free
IRQ8
Real-time clock
IRQ9
Software interrupt, rerouted to IRQ2
IRQ10
IF 964-DP, otherwise free
IRQ11
CP 1401, otherwise free
IRQ12
Assigned to trackball/mouse
IRQ13
Assigned to numeric coprocessor
IRQ14
Assigned to hard disk drive, otherwise free
IRQ15
Assigned