Fujitsu C122-E177-01EN ユーザーズマニュアル

ページ / 512
MMB Web-UI (Web User Interface) Operations 
 
Cancel 
Restores the original information and does not set the specified information, such as the date 
and time zone. 
 
(1)  Menu Operation 
[Network Configuration] - [Date/Time] 
 
(2)  Window Operations 
1. 
Specify information such as the date and time zone. Then, click the [Apply] button. 
This sets the information such as the date and time zone. 
 
[Message] 
 
The following table lists the messages displayed in this window. 
Message Number 
Message 
I_00013 
Setting completed. 
E_00020 
The IP address overlaps. 
E_00100 
Failed to set Date/Time information 
W_00414 
Invalid Date Format 
W_00434 
Invalid Time Format 
W_00433 
The duplicate IP address was found. 
W_00432 
Invalid IP Address specified. 
 
For details on the messages displayed on the window, see 
PRIMEQUEST 2000 Series Message Reference
 
(C122-E178EN). 
 
Time synchronization with NTP 
This section describes the operational specifications for the NTP client. 
 
When starting time synchronization: 
The NTP client on the MMB synchronizes the time at the start of operation, irrespective of the 
time difference with the NTP server. 
The NTP client on the MMB starts operation: 
when the NTP services on the MMB are enabled (i.e., when [Enable] in the [NTP] field 
is checked and the [Apply] button is clicked in the [Network Configuration] - [Date/Time] 
window), or 
when the MMB is reset, the MMB redundancy is switched, and the AC power is turned 
from OFF to ON while the NTP services on the MMB are enabled. 
 
When starting time synchronization: 
The time-adjusting method on the NTP varies depending on the NTP operation mode (Step mode 
or Slew mode). 
In Step mode, if the time difference between the synchronized NTP servers and the MMB is: 
(1)  within a range of -0.128 to +0.128 seconds, the NTP executes Slew adjustment, which 
corrects the time at a rate of up to 0.0005 per second without reversal. 
(2)  outside a range of -0.128 to +0.128 seconds and within a range of -1000 to +1000 
seconds, the NTP executes Step adjustment. (In this case, the clock may be reversed.) 
(3)  outside a range of -1000 to +1000 seconds, the NTP function stops. 
 
In Slew mode, if the time difference between the synchronized NTP servers and the MMB is: 
(1)  within a range of -600 to +600 seconds (10 minutes) , the NTP executes Slew 
adjustment, which corrects the time at a rate of up to 0.0005 per second without 
reversal. 
(2)  outside a range of -600 to +600 seconds (10 minutes) and within a range of -1000 to 
+1000 seconds (16 minutes and 40 seconds) , the NTP executes Step adjustment. (In 
this case, the clock may be reversed.) 
(3)  outside a range of -1000 to +1000 seconds (16 minutes and 40 seconds) , the NTP 
function stops. 
 
Time synchronization interval 
The NTP client synchronizes at an interval of 64 to 1024 seconds. The initial synchronization 
interval is 64 seconds. As the synchronization accuracy becomes stable, this interval gradually 
doubles from 64 seconds to 128 seconds, then to 256 seconds, then to 512 seconds, and finally 
to 1024 seconds.